Johnson Controls MS-IOM3733-0 Metasys IOM Input/Output Expansion Module Rev A

$399.00

  Your offer? or Question

Item Condition: Its Used Item

1 in stock



Description

Johnson Controls Metasys Input/Output Expansion Module

Model: MS-IOM3733-0 | Revision A | FC Bus Network Field Expansion Block

Condition Used / Tested Clean Working Condition — Authentic building automation asset pull. The structural enclosure, communication board terminals, address rotary dials, and full input/output channel contacts have been thoroughly cleaned, physically inspected, and bench-verified to ensure stable FC Bus communication and highly accurate point mapping.

Product Overview

The genuine Johnson Controls MS-IOM3733-0 Metasys IOM Expansion Module (Revision A) delivers robust, high-density Input/Output scalability for modernized building automation systems and advanced HVAC field control networks. Operating on a standard 24 VAC power supply, this flexible point multiplexer integrates seamlessly via the master Field Controller (FC) Bus to significantly scale your facility monitoring footprint. Outfitted with 17 total point configurations—including 8 versatile Universal Inputs, 4 precision Analog Outputs, and 5 rugged Relay Outputs rated at 2 Amps—it provides an efficient, dependable hardware solution for multi-point equipment monitoring, mechanical overhauls, and drop-in panel maintenance.

Technical Specifications

Parameter Specification Details
Brand / Manufacturer Johnson Controls (Genuine Original Equipment)
Model Identifier MS-IOM3733-0
Hardware Revision Revision A (Rev A)
Operating Voltage Input 24 VAC nominal, 50/60 Hz, Class 2 Power Source
Universal Inputs (UI) 8 Channels (Supports RTD, Thermistor, Current/Voltage, or Dry Contacts)
Analog Outputs (AO) 4 Channels (Configurable 0-10 VDC or 4-20 mA Command Signals)
Relay Outputs (RO) 5 Channels (Rated up to 30 VAC / 30 VDC, 2 Amps Maximum Load)
Network Communications RS-485 Serial Interface via Metasys FC Bus Protocol
Primary Applications Metasys Field Node Expansion, Air Handling Units (AHUs), Multi-Stage Fan Control, Industrial Plant Monitoring

Key Features & Operational Benefits

  • High Point-Density Expansion: Adds 17 diverse field points over a single network address, minimizing panel wiring clutter and extra controller hardware overhead.
  • Versatile Universal Inputs: Fully software-configurable loops allow smooth transitions between analog tracking elements and digital switch indicators without manual modifications.
  • Integrated Address Dials: Easy-to-use rotary switches allow quick decimal addressing configurations right on the sub-panel, shortening replacement setup steps.
  • Seamless Metasys Integration: Connects perfectly into existing FC Bus trunk architectures, reporting diagnostics directly to Metasys network engines (NAE/SNE/NCE).

Additional information

Brand

Johnson Controls

MPN

Model

Type

Shipping Policy

Shipping Policy

1. Handling & Delivery Times
Handling Time: All orders are processed and packed within 1–3 business days.
Delivery Time: Once shipped, international delivery typically takes 6–10 business days.
You will receive a tracking number via email as soon as your order dispatches.

2. International Flat-Rate Shipping
We ship worldwide using a fixed flat rate.
The exact shipping cost for your location will be displayed directly in your shopping cart before checkout.

3. Need a Lower Shipping Rate?

If you are ordering multiple items or need relief on shipping costs, please reach out to us before purchasing. We are happy to check alternative carriers to find you a more cost-effective option.

Contact Us
Email: heecotechnical@gmail.com
WhatsApp/Phone: +923702502354

Refund Policy

Returns & Refunds Policy
Thank you for shopping with us. We want to ensure you get the exact technical hardware you need. Please review our policy regarding returns and refunds below.

1. Return Window & Eligibility
15-Day Limit: You have 15 days from the date of delivery to request a return or refund.

Inspection Clause: All returned items are subject to a thorough technical inspection upon arrival. A refund or exchange will only be approved if the item passes inspection based on the valid issues outlined below.

2. Valid Reasons for a Return
A return request will be accepted only under the following specific circumstances:

Description Mismatch: The item has an issue or defect that was not mentioned or disclosed in the product description.

Wrong Item Delivered: The item received does not match the order you placed.

Visual Discrepancy: The item delivered does not match the product images shown on our store.

Specification Changes: The item delivered is a different model, version, or hardware revision than the one advertised and ordered.

3. Non-Returnable Conditions
Returns will not be accepted if:

The item was ordered by mistake due to buyer error (e.g., ordering the wrong voltage or specification without checking compatibility).

The item shows signs of installation, misuse, wiring damage, or alteration after delivery.

The request is made after the 15-day window has expired.

Cancellation / Return / Exchange Policy

4. The Refund Process
Approval: Once your return is received and inspected, we will notify you whether your refund is approved or rejected based on the item\'s condition and the reason for return.

Payout: Approved refunds will be processed back to your original method of payment within [5-7] business days.

Exchanges: If the issue is a wrong model or revision, we will happily exchange it for the correct item (subject to stock availability) at no extra shipping cost to you.

General Inquiries

There are no inquiries yet.